Leakage exceeds system capacity
Cloth tears, open sectors, seals, joints, valve wear or open drains can admit excess air.
BOYUN Industrial Filtration Solutions – Ceramic Vacuum Disc Filter
Diagnose low vacuum, air leakage and unstable filtration by checking seals, piping, valves, filtrate receivers, pumps, sector connections and cloth condition.

Record where vacuum is measured, instrument condition, operating state and whether the issue is low, unstable, zone-specific or associated with receiver level and filtrate flow.
Cloth tears, open sectors, seals, joints, valve wear or open drains can admit excess air.
Flooded receivers, restricted piping, blocked sectors or condensate can isolate the pump from the filter.
Pump condition, seal water, speed, valves, elevation and process load affect capacity.
Stop the equipment and isolate all hazardous energy that can cause rotation, vacuum, pressure, stored mechanical movement, electrical energization or chemical exposure. Follow the site lockout and permit procedure; inspection and maintenance must be performed only by authorized personnel.
Change one controlled variable at a time and retain the before-and-after operating evidence.
Compare an approved reference and measurement point.
Map zone, disc, operating state and timing.
Review levels, carryover and liquid removal.
Use approved isolation and inspection methods.
Compare pump and system performance to the basis.
Use the same instruments, sampling points and laboratory method so changes can be compared.
Never use hands, loose materials or unsafe sprays near rotating equipment to search for leakage.
| Finding | Review | Possible controlled response |
|---|---|---|
| Low everywhere | Common header, receiver, pump or major open path. | Check shared equipment and confirmed isolation points. |
| One zone is low | Valve timing, zone seal or branch restriction/leak. | Inspect the identified branch under safe isolation. |
| Vacuum fluctuates with receiver level | Liquid removal, control or carryover problem. | Restore stable receiver operation and transfer. |
| One disc or sector behaves differently | Cloth, sector, neck seal or local blockage. | Inspect the localized path and media. |
| Pump cannot reach prior baseline | Pump condition, seal water, speed or changed air load. | Compare to supplier curve and maintenance evidence. |
Use related technical and service pages to resolve the underlying cause.
These answers support project preparation; the final recommendation depends on the actual duty.