Pumps selected for the duty
The vacuum source, receiver and piping must supply the pressure and flow required by the cake without excessive installed margin.
BOYUN Industrial Filtration Solutions – Ceramic Vacuum Disc Filter
BOYUN’s TP Series is a continuous cloth-media vacuum disc filter designed for mineral plants that treat electricity as a lifecycle cost. Models from 6 to 120 m² combine matched vacuum equipment, controlled air flow and a low-resistance filtration path while maintaining the capacity and cake-moisture duty defined by the slurry.

An energy-efficient vacuum disc filter is more than a smaller motor. Useful savings come from reducing avoidable air leakage and pressure loss, selecting pumps for the real operating point and controlling the system without compromising cake formation or drying.
The vacuum source, receiver and piping must supply the pressure and flow required by the cake without excessive installed margin.
Pipe routing, valve condition, sector seals and suitable cloth reduce losses between the filter surface and the vacuum equipment.
Disc speed, slurry level, vacuum and blowback settings should follow actual feed behavior instead of one fixed assumption.
Annual electricity = measured average input kW × operating hours. Compare configurations at the same dry throughput, feed condition and moisture target.
Every restriction or air leak consumes part of the pressure available at the cloth. The TP design and operating plan focus on the whole path.
Stable solids concentration and agitation support even cake formation.
Vacuum and cloth permeability establish the filtration rate without unnecessary restriction.
Disc speed and drying arc provide the residence time needed for the target cake.
Seals, valve timing, receivers and piping protect vacuum at the filter sectors.
Blowback and cloth washing restore the surface for the next filtration cycle.
The TP Series is most relevant when a filter operates many hours per year and the plant can compare energy at a consistent production duty.
These configurations come from BOYUN’s current TP Series data sheet. Final pump count, installed power, dimensions and controls depend on the project’s design point and utilities.
| Model | Pipe | Area (m²) | Spindle | Vacuum pump | Agitator | Roots blower | Total power | Dimensions (mm) | Weight |
|---|---|---|---|---|---|---|---|---|---|
| TP6 | Bent | 6 | 3 | 15 | 4 | — | 22 | Project-specific | Project-specific |
| TP12 | Bent | 12 | 3 | 18.5 | 4 | — | 25.5 | 2630 × 3000 × 2800 | 2.6 |
| TP18 | Bent | 18 | 3 | 22 | 4 | — | 29 | 2930 × 3000 × 2800 | 3.1 |
| TP24 | Bent | 24 | 3 | 37 | 4 | — | 44 | 3230 × 3000 × 2800 | 3.4 |
| TP30 | Bent | 30 | 3 | 37 | 5.5 | — | 45.5 | 3530 × 3000 × 2930 | 3.8 |
| TP36 | Bent | 36 | 3 | 37 | 5.5 | 5.5 | 51 | 3830 × 3000 × 2930 | 4.2 |
| TP42 | Bent | 42 | 4 | 45 | 5.5 | 5.5 | 60 | 4130 × 3000 × 2930 | 4.6 |
| TP48 | Bent | 48 | 4 | 55 | 7.5 | 7.5 | 74 | 4430 × 3000 × 2930 | 5.0 |
| TP54 | Bent | 54 | 5.5 | 55 | 7.5 | 7.5 | 75.5 | 4730 × 3000 × 2930 | 5.4 |
| TP60 | Straight | 60 | 5.5 | 75 | 7.5 | 7.5 | 95.5 | 5030 × 3000 × 2930 | 6.2 |
| TP72 | Straight | 72 | 7.5 | 75 | 7.5 | 11 | 101.5 | 5060 × 3086 × 2980 | 7.2 |
| TP84 | Straight | 84 | 7.5 | 2 × 45 | 11 | 11 | 119.5 | 5480 × 3000 × 2930 | 8.2 |
| TP96 | Straight | 96 | 7.5 | 2 × 55 | 11 | 15 | 143.5 | 6260 × 3085 × 2930 | 8.9 |
| TP108 | Straight | 108 | 7.5 | 2 × 55 | 15 | 2 × 7.5 | 147.5 | Project-specific | Project-specific |
| TP120 | Straight | 120 | 11 | 2 × 75 | 15 | 22 | 198 | 8100 × 3100 × 2980 | 12.0 |
Use measured or estimated operating input, load profile and annual hours for lifecycle calculations.

BOYUN separates the process requirement from the energy calculation. The first step proves the filter can meet production and moisture. The second compares how much electrical input each complete configuration needs.
Compare kWh at equal tonnes of dry solids, not only motor nameplates.
A shorter drying arc can lower power and still fail the product specification.
Record average kW, vacuum, uptime and feed condition where existing equipment is available.
State whether pumps, blowers, agitators and auxiliaries are included in both alternatives.
When current operating data is unavailable, BOYUN can still compare candidate designs on one common duty and state the assumptions.
Energy is one decision variable. Cloth consumption, particle retention, maintenance practice and slurry response can change the best choice.
A broad-duty cloth-media platform when proven arrangement, flexible configurations and plant standardization lead the decision.
Compare the PG SeriesA cloth-free option for suitable fine concentrates where capillary filtration and ceramic plate cleaning fit the duty.
Compare the BY SeriesUse comparable operating data to turn an energy claim into a procurement decision.
Share current average kW, dry throughput, operating hours and moisture target. BOYUN will define the comparison boundary and recommend the next engineering step.